How a heat pump is specified
Two curves crossing, and everything that follows from where they meet
Sizing a heat pump is the intersection of two lines. The first is the building heat loss, which rises steadily as it gets colder outside and comes from a room by room calculation. The second is the equipment heating capacity, which falls as it gets colder, because the outdoor coil has less heat available to extract. Plot both against outdoor temperature and they cross at one point. That crossing is the balance point, and it is the single most informative number in the whole project.
Getting the equipment curve right requires the manufacturer extended performance data rather than the number on the brochure. Published heating capacity is commonly stated at a mild outdoor condition, and capacity at the temperature your building actually sees on a cold night can be considerably lower. Inverter driven cold climate equipment holds its output far better than older single speed units, which is why the arithmetic has genuinely changed in recent years, but the only way to know for a specific model is to read its tables.
Where the balance point lands drives the rest of the design. A high balance point means backup heat carries a large share of the season, which is expensive if that backup is electric resistance. A low balance point means the heat pump does almost everything, but usually implies larger or more capable equipment, and oversizing for winter can compromise summer dehumidification on a system that also cools. Inverter equipment with a wide turndown range eases that tension considerably, which is one of the strongest practical arguments for it.
The backup strategy then has to be an actual decision. Electric resistance is simple, cheap to install and expensive to run. An existing gas furnace retained as a dual fuel arrangement is often the lowest running cost option where gas is already present, with a switchover point set on economics rather than on capacity. Doing nothing and accepting a cold building below a certain temperature is occasionally reasonable in a very well insulated property. What is not acceptable is installing resistance strips, leaving the thermostat at factory defaults, and discovering the consequences in February.
| Design input | Where the figure comes from | What it decides |
|---|---|---|
| Building heat loss | Room by room calculation from construction and glazing | One of the two curves, and the capacity needed on a design day |
| Capacity at design temperature | Manufacturer extended performance tables | The other curve, and whether the headline rating was misleading |
| Balance point | Where the two curves cross | How much of the season backup heat has to carry |
| Backup type | Fuel availability, running cost and existing equipment | Operating cost for the coldest part of the year |
| Switchover setpoint | Relative cost per unit of heat from each source | Whether dual fuel actually saves money or just adds complexity |
| Turndown range | Inverter capability of the selected equipment | Whether winter sizing compromises summer dehumidification |
| Defrost strategy | Demand defrost capability of the control | Wasted energy and comfort dips across the heating season |
One practical note on outdoor unit siting, since it affects heating performance in a way it never does on a cooling only system. A heat pump running in winter produces condensate that freezes, so the unit needs to stand clear of the ground on a raised platform with drainage beneath it, away from roof drip lines and out of the path of snow shed. A unit sitting in a tray of ice loses coil surface, defrosts more often and works harder for less, and the remedy costs almost nothing at installation and considerably more afterwards.
Commissioning covers the usual refrigerant side work plus everything specific to the reversal: defrost operation observed through a full cycle, reversing valve shift confirmed in both directions, auxiliary staging tested to prove it energises only at the intended conditions, and the thermostat configuration written down. That last item matters more than it sounds, because a control configuration nobody recorded is one the next technician will reset to default.
Project sequence
Six stages of a heat pump project
The first three happen on paper, and they are where the outcome is actually decided.
Heat loss and gain
Both calculated, because the same equipment has to satisfy winter capacity and summer dehumidification.
Capacity modelling
Extended performance data read at local design temperature for each candidate model.
Balance point plot
The two curves drawn together and shown to you, so the backup question is answered with a picture rather than a claim.
Backup decision
Resistance, dual fuel or neither, chosen on running cost and what the building already has.
Installation
Refrigerant work to the same discipline as any cooling install, plus the control wiring the staging strategy requires.
Configure and document
Defrost verified, staging proven, every thermostat setting recorded and left with you in writing.
Handover pack
What you receive at the end of a heat pump project
The controls documentation is the part that protects the investment over time.
Customer testimonies
Feedback on heat pump projects
I was shown an actual chart with the two lines crossing. No other quote had mentioned backup heat at all.
They recommended keeping my gas furnace as the backup rather than fitting strips, and set the switchover on cost. My winter bills reflect that.
The thermostat settings were written on a card and taped inside the panel. A year later a different technician reset something and I could put it back.
Heat pump design questions
Balance points, dual fuel, sizing and cold weather performance
What exactly is a balance point?
It is the outdoor temperature at which the heat pump output exactly equals the heat the building is losing. Above it the equipment has spare capacity and cycles. Below it the equipment runs continuously and still cannot keep up, so something has to make up the shortfall.
Knowing that temperature tells you how many hours per season backup heat will run, which is what actually determines your winter operating cost. A balance point of twenty degrees and one of forty degrees describe completely different bills in the same building with the same equipment brand on the outside.
Is dual fuel better than electric backup?
Where gas is already present and the furnace is sound, usually yes. The heat pump handles mild and moderate conditions at high efficiency, the furnace takes over below a switchover temperature, and neither is asked to do the job it is bad at.
The switchover point should be set on relative running cost rather than on capacity, and it needs revisiting if energy prices move significantly. The trade off is complexity: two heat sources, two sets of maintenance, and a control strategy that has to be configured correctly or the system will make poor choices quietly.
Should the heat pump be sized for heating or for cooling?
This is the central tension in the design. Size for winter and the equipment may be too large for summer, satisfying the thermostat before it has removed enough moisture. Size for summer and you accept a higher balance point and more backup heat hours.
Inverter driven equipment with a wide turndown range largely resolves it, because the same machine can run at a low output in mild weather and a high output in cold. Where the budget does not stretch to that, we will show you both sizing options with their consequences rather than picking one quietly.
Will I need to change my ductwork?
Possibly, and it is worth checking early. Heat pumps deliver heat at a lower supply temperature than a furnace, which means moving more air to deliver the same heat. A duct system that was adequate for a furnace can be marginal for a heat pump in the same building.
The measurable version of that question is total external static pressure against the airflow the new equipment needs. We take that reading during the survey, so any duct work appears in the proposal as its own line rather than surfacing after installation as an explanation for disappointing performance.
Related services
Work that commonly accompanies a heat pump installation
Heat pump projects usually touch the distribution and the controls as much as the equipment.
Furnace Repair
Boiler Repair
Boiler Replacement
Heat Pump Repair
Ask for the balance point before you compare quotes
It is the number every other heat pump decision depends on, and most proposals in Townsend, MT never state it.